Hot Ionization Gauges


Bayard-Alpert Pirani Gauge BPG400

  • Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
  • Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
  • The Pirani interlock protects the Bayard-Alpert system from premature filament burnout and excess contamination from high pressure operation
  • Long-life yttrium oxide coated iridium filament
  • Optional graphic display and Fieldbus interfaces available
  • Automatic high vacuum Pirani adjustment reduces operator interventions
  • RoHS compliance
  • General vacuum measurement and control in the low to ultra high vacuum range


Bayard-Alpert Pirani Gauge BPG402-S

  • Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
  • Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
  • Pirani interlock protects the filament from premature burnout
  • Two long-life yttrium oxide coated iridium filaments
  • Optional graphic display and Fieldbus interfaces available
  • Automatic high vacuum Pirani adjustment reduces operator interventions
  • Easy to exchange sensing element with on-board calibration data guarantees high reproducibility
  • RoHS compliance


High Pressure Ionization Pirani Gauge HPG400

  • HPG400 saves cost and tool space and reduces the complexity of vacuum system installation and setup
  • The high pressure hot ion gauge delivers accurate, reliable pressure measurements from 1×10-5 … 1 mbar for improved process control
  • User selectable hot ion emission activation between 5×10-2 and 1 mbar
  • Pirani interlock protects the hot filament from premature burnout
  • Optional graphic display and Fieldbus interfaces available
  • Automatic high vacuum Pirani adjustment reduces operator interventions
  • RoHS compliance


Bayard-Alpert Pirani Capacitance Diaphragm Gauge – TripleGauge BCG450

  • BCG450 saves cost and tool space and reduces the complexity of vacuum measurement installation and setup
  • Gas-type-independent pressure measurement above 10 Torr provides more reliable loadlock control for any gas mixture
  • Pirani interlock protects the hot filament from premature burnout
  • Automatic high vacuum Pirani adjustment reduces operator interventions
  • Differential pressure measurement at atmosphere eliminates uncertainty related to atmospheric pressure changes
  • Easy-to-exchange sensing element with on-board calibration data guarantees reproducibility
  • Optional graphic display and Fieldbus interfaces available
  • RoHS compliance